Schneideri kontaktorid. Lai valik tooteid kohe laos olemas.
-
LC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER
LC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER
€42.00 +KMLC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER
€42.00 +KM -
LC1D12P7 TeSys KONTAKTOR 12A, 230V SCHNEIDER
LC1D12P7 TeSys KONTAKTOR 12A, 230V SCHNEIDER
€24.00 +KMLC1D12P7 TeSys KONTAKTOR 12A, 230V SCHNEIDER
€24.00 +KM -
LC1D25P7 TeSysKONTAKTOR 25A 230VAC SCHNEIDER
LC1D25P7 TeSysKONTAKTOR 25A 230VAC SCHNEIDER
€44.00 +KMLC1D25P7 TeSysKONTAKTOR 25A 230VAC SCHNEIDER
€44.00 +KM -
LC1D32P7 TeSys KONTAKTOR 32A, 230V SCHNEIDER
LC1D32P7 TeSys KONTAKTOR 32A, 230V SCHNEIDER
€64.00 +KMLC1D32P7 TeSys KONTAKTOR 32A, 230V SCHNEIDER
€64.00 +KM -
LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER
LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor control
Resistive loadutilisation category AC-1
AC-4
AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
Power circuit <= 300 V DC[Ie] rated operational current 50 A 60 °C) <= 440 V AC AC-3 power circuit
80 A 60 °C) <= 440 V AC AC-1 power circuitmotor power kW 15 kW 220…230 V AC 50/60 Hz AC-3)
22 kW 380…400 V AC 50/60 Hz AC-3)
30 kW 500 V AC 50/60 Hz AC-3)
33 kW 660…690 V AC 50/60 Hz AC-3)
25 kW 415 V AC 50/60 Hz AC-3)
30 kW 440 V AC 50/60 Hz AC-3)
11 kW 400 V AC 50/60 Hz AC-4)motor power HP (UL / CSA) 3 hp 115 V AC 50/60 Hz 1 phase
7,5 hp 230/240 V AC 50/60 Hz 1 phase
15 hp 200/208 V AC 50/60 Hz 3 phases
15 hp 230/240 V AC 50/60 Hz 3 phases
40 hp 460/480 V AC 50/60 Hz 3 phases
40 hp 575/600 V AC 50/60 Hz 3 phasescontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 230 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A 60 °C signalling circuit
80 A 60 °C power circuitIrms rated making capacity 140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
900 A 440 V power circuit IEC 60947rated breaking capacity 900 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 400 A 40 °C – 10 s power circuit
810 A 40 °C – 1 s power circuit
84 A 40 °C – 10 min power circuit
208 A 40 °C – 1 min power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-1
100 A gG <= 690 V type 1 power circuit
100 A gG <= 690 V type 2 power circuitaverage impedance 1,5 mOhm – Ith 80 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1electrical durability 1,45 Mcycles 50 A AC-3 <= 440 V
1,1 Mcycles 80 A AC-1 <= 440 Vpower dissipation per pole 3,7 W AC-3
9,6 W AC-1Front cover Withmounting support Plate
Railstandards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508product certifications GL
BV
GOST
CCC
CSA
UL
RINA
LROS (Lloyds register of shipping)
DNVconnections – terminals Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
Power circuit screw connection 1 1…35 mm²flexible without cable end
Power circuit screw connection 2 1…25 mm²flexible without cable end
Power circuit screw connection 1 1…35 mm²flexible with cable end
Power circuit screw connection 2 1…25 mm²flexible with cable end
Power circuit screw connection 1 1…35 mm²solid without cable end
Power circuit screw connection 2 1…25 mm²solid without cable endtightening torque Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2
Power circuit 8 N.m EverLink BTR screw connectors 25…35 mm² hexagonal 4 mm
Power circuit 5 N.m EverLink BTR screw connectors 1…25 mm² hexagonal 4 mmoperating time 4…19 ms opening
12…26 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 6 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits 0.3…0.6 Uc −40…70 °C drop-out AC 50/60 Hz
0.8…1.1 Uc −40…60 °C operational AC 50 Hz
0.85…1.1 Uc −40…60 °C operational AC 60 Hz
1…1.1 Uc 60…70 °C operational AC 50/60 Hzinrush power in VA 140 VA 60 Hz 0,75 20 °C)
160 VA 50 Hz 0,75 20 °C)hold-in power consumption in VA 13 VA 60 Hz 0,3 20 °C)
15 VA 50 Hz 0,3 20 °C)heat dissipation 4…5 W 50/60 Hzauxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25…400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitcontact compatibility M2compatibility code LC1Dmotor power range 7…11 kW 200…240 V 3 phases
15…25 kW 380…440 V 3 phases
15…25 kW 200…240 V 3 phases
30…50 kW 380…440 V 3 phases
30…50 kW 480…500 V 3 phasesmotor starter type Direct on-line contactorcontactor coil voltage 230 V AC standard€98.00 +KMLC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER
€98.00 +KM