Schneideri kontaktorid. Lai valik tooteid kohe laos olemas.

  • LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER

    LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER

    Main
    range
    TeSys
    product name
    TeSys D
    product or component type
    Contactor
    device short name
    LC1D
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-4
    AC-3
    poles description
    3P
    power pole contact composition
    3 NO
    [Ue] rated operational voltage
    Power circuit <= 690 V AC 25…400 Hz
    Power circuit <= 300 V DC
    [Ie] rated operational current
    50 A 60 °C) <= 440 V AC AC-3 power circuit
    80 A 60 °C) <= 440 V AC AC-1 power circuit
    motor power kW
    15 kW 220…230 V AC 50/60 Hz AC-3)
    22 kW 380…400 V AC 50/60 Hz AC-3)
    30 kW 500 V AC 50/60 Hz AC-3)
    33 kW 660…690 V AC 50/60 Hz AC-3)
    25 kW 415 V AC 50/60 Hz AC-3)
    30 kW 440 V AC 50/60 Hz AC-3)
    11 kW 400 V AC 50/60 Hz AC-4)
    motor power HP (UL / CSA)
    3 hp 115 V AC 50/60 Hz 1 phase
    7,5 hp 230/240 V AC 50/60 Hz 1 phase
    15 hp 200/208 V AC 50/60 Hz 3 phases
    15 hp 230/240 V AC 50/60 Hz 3 phases
    40 hp 460/480 V AC 50/60 Hz 3 phases
    40 hp 575/600 V AC 50/60 Hz 3 phases
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    230 V AC 50/60 Hz
    auxiliary contact composition
    1 NO + 1 NC
    [Uimp] rated impulse withstand voltage
    6 kV IEC 60947
    overvoltage category
    III
    [Ith] conventional free air thermal current
    10 A 60 °C signalling circuit
    80 A 60 °C power circuit
    Irms rated making capacity
    140 A AC signalling circuit IEC 60947-5-1
    250 A DC signalling circuit IEC 60947-5-1
    900 A 440 V power circuit IEC 60947
    rated breaking capacity
    900 A 440 V power circuit IEC 60947
    [Icw] rated short-time withstand current
    400 A 40 °C – 10 s power circuit
    810 A 40 °C – 1 s power circuit
    84 A 40 °C – 10 min power circuit
    208 A 40 °C – 1 min power circuit
    100 A – 1 s signalling circuit
    120 A – 500 ms signalling circuit
    140 A – 100 ms signalling circuit
    associated fuse rating
    10 A gG signalling circuit IEC 60947-5-1
    100 A gG <= 690 V type 1 power circuit
    100 A gG <= 690 V type 2 power circuit
    average impedance
    1,5 mOhm – Ith 80 A 50 Hz power circuit
    [Ui] rated insulation voltage
    Power circuit 600 V CSA
    Power circuit 600 V UL
    Signalling circuit 690 V IEC 60947-1
    Signalling circuit 600 V CSA
    Signalling circuit 600 V UL
    Power circuit 690 V IEC 60947-4-1
    electrical durability
    1,45 Mcycles 50 A AC-3 <= 440 V
    1,1 Mcycles 80 A AC-1 <= 440 V
    power dissipation per pole
    3,7 W AC-3
    9,6 W AC-1
    Front cover
    With
    mounting support
    Plate
    Rail
    standards
    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    product certifications
    GL
    BV
    GOST
    CCC
    CSA
    UL
    RINA
    LROS (Lloyds register of shipping)
    DNV
    connections – terminals
    Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
    Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
    Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
    Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
    Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
    Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
    Power circuit screw connection 1 1…35 mm²flexible without cable end
    Power circuit screw connection 2 1…25 mm²flexible without cable end
    Power circuit screw connection 1 1…35 mm²flexible with cable end
    Power circuit screw connection 2 1…25 mm²flexible with cable end
    Power circuit screw connection 1 1…35 mm²solid without cable end
    Power circuit screw connection 2 1…25 mm²solid without cable end
    tightening torque
    Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
    Control circuit 1,7 N.m screw clamp terminals Philips No 2
    Power circuit 8 N.m EverLink BTR screw connectors 25…35 mm² hexagonal 4 mm
    Power circuit 5 N.m EverLink BTR screw connectors 1…25 mm² hexagonal 4 mm
    operating time
    4…19 ms opening
    12…26 ms closing
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    mechanical durability
    6 Mcycles
    maximum operating rate
    3600 cyc/h 60 °C
    Complementary
    coil technology
    Without built-in suppressor module
    control circuit voltage limits
    0.3…0.6 Uc −40…70 °C drop-out AC 50/60 Hz
    0.8…1.1 Uc −40…60 °C operational AC 50 Hz
    0.85…1.1 Uc −40…60 °C operational AC 60 Hz
    1…1.1 Uc 60…70 °C operational AC 50/60 Hz
    inrush power in VA
    140 VA 60 Hz 0,75 20 °C)
    160 VA 50 Hz 0,75 20 °C)
    hold-in power consumption in VA
    13 VA 60 Hz 0,3 20 °C)
    15 VA 50 Hz 0,3 20 °C)
    heat dissipation
    4…5 W 50/60 Hz
    auxiliary contacts type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1
    Mirror contact 1 NC IEC 60947-4-1
    signalling circuit frequency
    25…400 Hz
    minimum switching current
    5 mA signalling circuit
    minimum switching voltage
    17 V signalling circuit
    non-overlap time
    1,5 ms on de-energisation between NC and NO contact
    1,5 ms on energisation between NC and NO contact
    insulation resistance
    > 10 MOhm signalling circuit
    contact compatibility
    M2
    compatibility code
    LC1D
    motor power range
    7…11 kW 200…240 V 3 phases
    15…25 kW 380…440 V 3 phases
    15…25 kW 200…240 V 3 phases
    30…50 kW 380…440 V 3 phases
    30…50 kW 480…500 V 3 phases
    motor starter type
    Direct on-line contactor
    contactor coil voltage
    230 V AC standard

Main Menu