LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER

98.00 +KM

1 in stock

LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER

Main
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-4
AC-3
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25…400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current
50 A 60 °C) <= 440 V AC AC-3 power circuit
80 A 60 °C) <= 440 V AC AC-1 power circuit
motor power kW
15 kW 220…230 V AC 50/60 Hz AC-3)
22 kW 380…400 V AC 50/60 Hz AC-3)
30 kW 500 V AC 50/60 Hz AC-3)
33 kW 660…690 V AC 50/60 Hz AC-3)
25 kW 415 V AC 50/60 Hz AC-3)
30 kW 440 V AC 50/60 Hz AC-3)
11 kW 400 V AC 50/60 Hz AC-4)
motor power HP (UL / CSA)
3 hp 115 V AC 50/60 Hz 1 phase
7,5 hp 230/240 V AC 50/60 Hz 1 phase
15 hp 200/208 V AC 50/60 Hz 3 phases
15 hp 230/240 V AC 50/60 Hz 3 phases
40 hp 460/480 V AC 50/60 Hz 3 phases
40 hp 575/600 V AC 50/60 Hz 3 phases
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
10 A 60 °C signalling circuit
80 A 60 °C power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
900 A 440 V power circuit IEC 60947
rated breaking capacity
900 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
400 A 40 °C – 10 s power circuit
810 A 40 °C – 1 s power circuit
84 A 40 °C – 10 min power circuit
208 A 40 °C – 1 min power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1
100 A gG <= 690 V type 1 power circuit
100 A gG <= 690 V type 2 power circuit
average impedance
1,5 mOhm – Ith 80 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
electrical durability
1,45 Mcycles 50 A AC-3 <= 440 V
1,1 Mcycles 80 A AC-1 <= 440 V
power dissipation per pole
3,7 W AC-3
9,6 W AC-1
Front cover
With
mounting support
Plate
Rail
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
GL
BV
GOST
CCC
CSA
UL
RINA
LROS (Lloyds register of shipping)
DNV
connections – terminals
Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
Power circuit screw connection 1 1…35 mm²flexible without cable end
Power circuit screw connection 2 1…25 mm²flexible without cable end
Power circuit screw connection 1 1…35 mm²flexible with cable end
Power circuit screw connection 2 1…25 mm²flexible with cable end
Power circuit screw connection 1 1…35 mm²solid without cable end
Power circuit screw connection 2 1…25 mm²solid without cable end
tightening torque
Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2
Power circuit 8 N.m EverLink BTR screw connectors 25…35 mm² hexagonal 4 mm
Power circuit 5 N.m EverLink BTR screw connectors 1…25 mm² hexagonal 4 mm
operating time
4…19 ms opening
12…26 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
6 Mcycles
maximum operating rate
3600 cyc/h 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3…0.6 Uc −40…70 °C drop-out AC 50/60 Hz
0.8…1.1 Uc −40…60 °C operational AC 50 Hz
0.85…1.1 Uc −40…60 °C operational AC 60 Hz
1…1.1 Uc 60…70 °C operational AC 50/60 Hz
inrush power in VA
140 VA 60 Hz 0,75 20 °C)
160 VA 50 Hz 0,75 20 °C)
hold-in power consumption in VA
13 VA 60 Hz 0,3 20 °C)
15 VA 50 Hz 0,3 20 °C)
heat dissipation
4…5 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
contact compatibility
M2
compatibility code
LC1D
motor power range
7…11 kW 200…240 V 3 phases
15…25 kW 380…440 V 3 phases
15…25 kW 200…240 V 3 phases
30…50 kW 380…440 V 3 phases
30…50 kW 480…500 V 3 phases
motor starter type
Direct on-line contactor
contactor coil voltage
230 V AC standard
Compare

LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER

Main Menu

LC1D50AP7 KONTAKTOR 50A 230VAC 3P SCHNEIDER

98.00 +KM

Add to Cart