LC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER

42.00 +KM

1 in stock

LC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER

Compare

LC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER

Main
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-4
AC-1
AC-3
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25…400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current
9 A 60 °C) <= 440 V AC AC-3 power circuit
25 A 60 °C) <= 440 V AC AC-1 power circuit
motor power kW
2,2 kW 220…230 V AC 50/60 Hz AC-3)
4 kW 380…400 V AC 50/60 Hz AC-3)
4 kW 415…440 V AC 50/60 Hz AC-3)
5,5 kW 500 V AC 50/60 Hz AC-3)
5,5 kW 660…690 V AC 50/60 Hz AC-3)
2,2 kW 400 V AC 50/60 Hz AC-4)
motor power HP (UL / CSA)
1 hp 230/240 V AC 50/60 Hz 1 phase
2 hp 200/208 V AC 50/60 Hz 3 phases
2 hp 230/240 V AC 50/60 Hz 3 phases
5 hp 460/480 V AC 50/60 Hz 3 phases
7,5 hp 575/600 V AC 50/60 Hz 3 phases
0,33 hp 115 V AC 50/60 Hz 1 phase
control circuit type
DC standard
[Uc] control circuit voltage
24 V DC
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
25 A 60 °C power circuit
10 A 60 °C signalling circuit
Irms rated making capacity
250 A 440 V power circuit IEC 60947
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
105 A 40 °C – 10 s power circuit
210 A 40 °C – 1 s power circuit
30 A 40 °C – 10 min power circuit
61 A 40 °C – 1 min power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1
25 A gG <= 690 V type 1 power circuit
20 A gG <= 690 V type 2 power circuit
average impedance
2,5 mOhm – Ith 25 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
electrical durability
0,6 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 9 A AC-3 <= 440 V
power dissipation per pole
1,56 W AC-1
0,2 W AC-3
Front cover
With
mounting support
Plate
Rail
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
LROS (Lloyds register of shipping)
CSA
UL
GOST
DNV
CCC
GL
BV
RINA
connections – terminals
Power circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Power circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Power circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Power circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Power circuit screw clamp terminals 1 1…4 mm²solid without cable end
Power circuit screw clamp terminals 2 1…4 mm²solid without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
tightening torque
Power circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Power circuit 1,7 N.m screw clamp terminals Philips No 2
Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2
operating time
53.55…72.45 ms closing
16…24 ms opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
30 Mcycles
maximum operating rate
3600 cyc/h 60 °C
Complementary
coil technology
Built-in bidirectional peak limiting diode suppressor
control circuit voltage limits
0.1…0.25 Uc −40…70 °C drop-out DC
0.7…1.25 Uc −40…60 °C operational DC
1…1.25 Uc 60…70 °C operational DC
time constant
28 ms
inrush power in W
5,4 W 20 °C)
hold-in power consumption in W
5,4 W 20 °C
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
contact compatibility
M4
compatibility code
LC1D
motor power range
1,1…2 kW 200…240 V 3 phases
2,2…3 kW 380…440 V 3 phases
4…6 kW 380…440 V 3 phases
4…6 kW 480…500 V 3 phases
motor starter type
Direct on-line contactor
contactor coil voltage
24 V DC standard

Main Menu

LC1D09BD TeSys KONTAKTOR 9A, 24VDC SCHNEIDER

42.00 +KM

Add to Cart